WNS series horizontal fuel gas steam boiler

WNS series full active fuel (gas) steam boilers (utility model patents), adopting a horizontal three-return wet back structure, thereby improving the boiler operating environment and improving boiler combustion compliance and service life. All the flue gas channels of the boiler are placed in the water, and the tail is equipped with a waste water tank and a perfect thermal insulation outsourcing design. Smoke box sealed with labyrinth

product description

WNS series horizontal fuel gas steam boiler

WNS series full active fuel (gas) steam boilers (utility model patents), adopting a horizontal three-return wet back structure, thereby improving the boiler operating environment and improving boiler combustion compliance and service life.

All the flue gas channels of the boiler are placed in the water, and the tail is equipped with a waste water tank and a perfect thermal insulation outsourcing design. The sealing of the cigarette box adopts a labyrinth structure, which avoids the occurrence of smoke leakage signs in the cigarette box.

The boiler heat obeys more than 90%, and adopts the combination of corrugated furnace and conical furnace with superior expansion performance. The size of the furnace bladder is consistent with the flame, and the area of the flue gas flow is reduced in turn, so that the flue gas flows at the same speed, and the heat exchange time of the high-temperature flue gas in the furnace is achieved to achieve a good heat transfer result.

High-performance burner with fully active adjustment that effectively matches the boiler. This burner burns fully and saves fuel, thereby effectively reducing the pollution caused by the combustion of the boiler to the environment.

The use of ultra-fine glass wool with high thermal insulation performance reduces heat loss.

Adopting intelligent energy-saving control system, boiler and steam supply (water supply) system can combine different loads to adjust fuel supply to achieve more energy-saving purposes.

The installation of the boiler adopts the group quick installation method, which has no special requirements on the foundation, does not require anchor bolts, and is easy to install.

Adopting the moving burner structure, it can not only match various burners, but also replace the burner and repair the furnace body more conveniently and quickly.

The front and rear smoke boxes adopt a removable structure, which can easily inspect, maintain and maintain the interior of the boiler.

This type of boiler is a newly developed new active fuel (gas) steam boiler with fresh product design, reasonable structure and superior process performance.

Model / item / parameter WNS0.5-0.4 (0.7) -Y (Q) WNS0.7-0.4 (0.7) -Y (Q) WNS1-0.7 (1.25) -Y (Q) WNS1.5-1.25-Y (Q) WNS2-1.25-Y (Q) WNS3-1.25-Y (Q)
Rated evaporation (t / h) 0.5 0.7 1 1.5 2 3
Rated working pressure (MPa) 0.4 (0.7) 0.4 (0.7) 0.7 (1.25) 1.25 1.25 1.25
Steam temperature (℃) 151 (170) 170 (194) 194 194 194
Design efficiency (%) 91-95
Water volume (m3) 1.2 1.56 2.10 2.7 2.7 5.9
Full water weight (t) 4.48 (5) 5.76 (6.2) 6.48 (7.1) 8 (8.4) 8 (8.4) 16 (16.8)
Power consumption (Kw) 3.6 3.6 5.9 15.8 17.7 19.7
Power (V) 380
Applicable fuel Light oil, natural gas, heavy oil, city gas, petroleum liquefied gas
Light oil (kg / h) 34 51 65 102 136 204
Natural gas (m3 / h) 8-41 12-60 17-85 24-120 40-210 45-260
Heavy oil (kg / h) 13.5-38.0 21.0-50.6 16.9-71.6 33.7-109.0 42.2-134.9 74-270
City gas (m3 / h) 92 138 184 276 368 552
Petroleum liquefied gas (m3 / h) 14 20 26 39 52 79
Length * width * height (mm) 2650 * 1600 * 1700 2650 * 1600 * 1800 3650 * 1800 * 1800 5200 * 2300 * 2400 5200 * 2300 * 2400 5570 * 3200 * 2670
Installation size Inlet / outlet valve diameter (mm) 50 65 65 65 65 100
Sewage valve diameter (mm) 40 40 40 40 40 40
Caliber of safety valve (mm) 40 2 * 40 2 * 40 2 * 50 2 * 50 2 * 65
Chimney diameter ф (mm) 250 300 320 360 360 360


Model / item / parameter WNS4-1.25 (1.6) -Y (Q) WNS5 -1.25 (1.6) -Y (Q) WNS6-1.25 (1.6) -Y (Q) WNS8 -1.25 (1.6) -Y (Q) WNS10 -1.25 (1.6) -Y (Q) WNS15 -1.25 (1.6) -Y (Q) WNS20 -1.25 (1.6) -Y (Q)
Rated thermal power (MW) 4 5 6 8 10 15 20
Rated working pressure (MPa) 1.25 (1.6)
Steam temperature (℃) 194 (204)
Boiler design efficiency (%) 85% -92%
Water volume (m3) 7.14 10 10.2 13.9 16.7 30 30
Power consumption (KW) 22.2 34.4 34.4 36 36 72 72
Power (V) 380
Applicable fuel Light oil, natural gas, heavy oil, city gas, petroleum liquefied gas
Light oil (kg / h) 272 241 382 482 603 904 1206
Natural gas (m3 / h) 328 413 429 429 715 1075 1430
Heavy oil (kg / h) 280 352 377 377 628 942 1256
City gas (m3 / h) 736 922 972 972 1620 2430 3240
Petroleum liquefied gas (m3 / h) 105 131 139 139 231 347 462
Length * width * height (mm) 5600 * 3300 * 2880 6020 * 3300 * 3060 7200 * 3300 * 3060 7300 * 3300 * 3060 7400 * 3300 * 3060 8100 * 4200 * 4100 8500 * 4500 * 4100
Installation size Inlet / outlet valve diameter (mm) 100 125 125 150 150 200 200
Sewage valve diameter (mm) 2 * 40 2 * 40 2 * 40 2 * 40 2 * 40 2 * 40 2 * 40
Caliber of safety valve (mm) 2 * 50 50 * 80 50 * 80 2 * 80 2 * 80 2 * 80 2 * 100
Chimney diameter ф (mm) 530 530 530 680 380 1000 1200