网赌网站送彩金诱饵

Welcome to the official authorized website of Henan Yongxing Boiler Group Co., Ltd.!

CLSS Fully Active Methanol-fired Hot Water Boiler

The CLSS type automatic methanol-fired hot water boiler is a quick-installed vertical internal combustion three-pass fire tube structure. The offset furnace bile wet-back arrangement is adopted, and the high-temperature flue gas sequentially flushes the second and third return smoke pipes, and then is discharged into the atmosphere from the rear smoke chamber through the chimney. The boiler is equipped with world brand burners. It adopts advanced technologies such as automatic combustion proportional adjustment, automatic feed water adjustment, program start and stop, and automatic operation. It also has automatic protection functions such as operating water temperature control, over-temperature and over-pressure flameout. This type of boiler has the characteristics of compact structure, safety, easy operation, rapid installation, less pollution, low noise, high efficiency, etc. It is widely used in enterprises, hotels, hospitals, offices, civil buildings and other facilities for industrial steam and living and heating. 1.CLSS-type methanol-fired boiler is vertical

product description


The CLSS full-active methanol-fired hot water boiler is a fast-mounted vertical internal combustion three-pass fire tube structure. The offset furnace bile wet-back arrangement is adopted, and the high-temperature flue gas sequentially flushes the second and third return smoke pipes, and then is discharged into the atmosphere from the rear smoke chamber through the chimney. The boiler is equipped with world brand burners, adopting advanced technologies such as active combustion proportional adjustment, active feed water adjustment, program start and stop, and active operation, and has active cherishing functions such as operating water temperature control, overtemperature, and overpressure flameout. This type of boiler has the characteristics of compact structure, safety, easy operation, quick installation, low pollution, low noise, high obedience, etc. It is widely used in enterprises, hotels, hospitals, office buildings, civil buildings and other facilities for industrial steam and living and heating.

1. The CLSS methanol-fired boiler is a vertical fast-mounted internal combustion three-pass fire tube boiler. The offset furnace bile wet-back structure is adopted. The high-temperature flue gas sequentially flushes the second and third return smoke pipes, and then is discharged into the atmosphere from the rear smoke chamber through the chimney. The group layout is compact and beautiful in shape.
2. Reasonable heating surface structure, useful for controlling smoke resistance.
3. Properly control the temperature of the exhaust gas, that is, the boiler obeys, and prevents the flue gas from condensing, extending the life of the boiler.
4. The boiler is equipped with a moving smoke box cover, which makes the boiler convenient for maintenance.
5. Equipped with explosion-proof door, it will actively rebound after pressure relief to ensure boiler safety.
6. The application of enhanced heat transfer elements such as corrugated furnace liners and threaded smoke pipes not only enhances the heat transfer results, but also uses the thermal expansion and contraction of the furnace body.

model
CLSS0.12-
95 / 70-Y (Q)
CLSS0.24-
95 / 70-Y (Q)
CLSS0.35-
95 / 70-Y (Q)
CLSS0.42-
95 / 70-Y (Q)
CLSS0.7-
95 / 70-Y (Q)
Rated thermal power (MW)
0.12
0.24
0.35
0.42
0.7
Rated thermal power (KCAL / H)
100,000
200 thousand
300000
400000
600000
Rated pressure (MPA)
Atmospheric
Atmospheric
Atmospheric
Atmospheric
Atmospheric
Heating area (㎡)
1250
2500
3750
5000
7500
Water temperature (℃)
95
95
95
95
95
Backwater temperature (℃)
70
70
70
70
70
Boiler thermal efficiency (%)
94
94
94
94
94
Applicable fuel
Light oil, heavy oil, natural gas, liquefied gas, city gas
Diesel consumption (KG / H)
11.6
23.2
33.86
45.46
63.3
Natural gas consumption (NM3 / H)
13.2
26.3
39
54.6
78
Liquefied gas consumption (NM3 / H)
4.3
8.6
13
18
25.6
Exhaust temperature (℃)
139
139
139
139
139
Outlet diameter (MM)
DN32
DN32
DN50
DN50
DN50
Backwater caliber (MM)
DN32
DN32
DN50
DN50
DN50
Sewage valve caliber (MM)
DN32
DN32
DN50
DN50
DN50
Total weight (T)
1.38
1.68
1.92
2.17
2.64
Overall size (MM)
Ф720 × 1360
Ф900 × 1750
Ф1160 × 1850
Ф1260 × 1970
Ф1500 × 2250